- D0-Fuse switch disconnector (for DIN rail mounting)
- Bus Bar System 60mm
- NH-fuse switch disconnector (for panel mounting)
- Bus Bar System 100/185mm
- Fuse accessories
- Supervisory relays
- Digital electric meter
- Accessories
- Bus Bar System 60mm
- Bus Bar System 60mm
Supervisory relay
- 3-phase supervision for low voltage and phase failure
- Neutral supervision
- Width 17,8mm (1 unit)
- Switching voltage 85%, delay 0,5 sec;
- Accords to DIN EN 50172 (DIN VDE 108-100)
- Power consumption less than 1W
- LED indication for phase and neutral faults
Price list
Item | Item-No. | kg/pc. | Packaging | €/pc. |
---|
Low voltage measuring relay 2 break contacts | 10 3059 | 0,10 | 1/18 | 33,91 |
Low voltage measuring relay 1 break contact | 10 3060 | 0,10 | 1/18 | 38,00 |
Undervoltage monitoring relay 2 change-over contacts with Phase display | 10 3069 | 0,10 | 1/18 | 39,00 |
Low voltage measuring relay
with rotary field recognition
- 3-phase supervision for low voltage and phase failure
- Neutral supervision
- Width 17,8mm (1 unit)
- Switching voltage 85%, delay 0,5 sec
- Accords to DIN EN 50172 (DIN VDE 108-100)
- Power consumption less than 1W
- LED indication for phase and neutral faults, phase and N-fault
- Test key
Price list
Item | Item-No. | kg/pc. | Packaging | €/pc. |
---|
Low voltage-measure relay with phase recognition 2 break contacts | 10 3061 | 0,10 | 1/18 | 40,58 |
Low voltage measuring relay
with switch back delay
- 3-phase supervision for low voltage and phase failure
- Neutral supervision
- Width 17,8mm (1 unit)
- Switching voltage 85%, delay 0,5 sec
- Switch back delay
- Power consumption less than 1W
- LED indication for phase and neutral faults
Price list
Item | Item-No. | kg/pc. | Packaging | €/pc. |
---|
Low voltage measuring relay 2 break contacts | 10 3062 | 0,10 | 1/18 | 40,58 |
Adjustable undervoltage monitoring relay
- 3-phase monitoring for undervoltage, phase failure and phase sequence
- Monitoring of N conductor
- Overall width 17.8 mm (1TE)
- Adjustable switching voltage
- Adjustable delay
- Power consumption less than 1 W
- LED error display
- Single-phase use possible
Price list
Item | Item-No. | kg/pc. | €/pc. |
---|
Undervoltage monitoring relay 2 change-over contacts | 10 3066 | 1 | 46,50 |
Undervoltage/overvoltage monitoring relay 230/400 V AC
- 3-phase monitoring for undervoltage, overvoltage, phase failure and phase sequence
- Monitoring of N conductor
- Overall width 17.8 mm (1TE)
- Adjustable undervoltage/overvoltage
- Power consumption less than 1 W
- LED error display
- Single-phase use possible
Price list
Item | Item-No. | kg/pc. | €/pc. |
---|
Undervoltage/overvoltage monitoring relay 2 change-over contacts | 10 3067 | 1 | 47,50 |
Undervoltage/overvoltage monitoring relay DC
- Undervoltage/overvoltage monitoring for DC
- Selectable voltage ranges 24 V/60 V/110 V/220 V DC
- Overall width 17.8 mm (1TE)
- Adjustable undervoltage/overvoltage
- Power consumption less than 1 W
- LED error display for undervoltage/overvoltage
Price list
Item | Item-No. | kg/pc. | €/pc. |
---|
Undervoltage/overvoltage monitoring relay 2 change-over contacts DC | 10 3068 | 1 | 48,50 |
Phase display
- Undervoltage/overvoltage monitoring for DC
- Display of all 3 phases with green LED (phase to N)
- LED display at L1 with DC (L1+/N-)
- Overall width 17.8 mm (1TE)
- Power consumption less than 1 W
- Voltage range 85-690 V AC/DC
Price list
Item | Item-No. | kg/pc. | €/pc. |
---|
Phase display | 10 3009 | 1 | 16,50 |
Technical data
Operation temperature | -25/+60°C |
Temperature Range Storage | -25/+60°C |
Climate stability (DIN EN 0160/IEC 68) | F / DIN 40040 |
Insulation parts | Plastic halogen and phosphate free |
Filament examination | 960° |
leakage current resistance | CTI 600 |
Protection class / contact protection | Finger and back of hand protection BGV A3 |
- Housing | IP 40 |
- Terminal | IP 20 |
Mounting | 35mm mounting rail fastener DIN EN 50022 |
High voltage class (VDE 0100) | III |
Degree of pollution | 2 |
EMV-compatibility | as per IEC 801 Part 1-4 |
Supply | |
Rated operational voltage | 230/400V AC |
Power consumption | < 1VA |
Rated frequency | 50-60Hz |
Rated electric strength Uimp | 4000V |
Series fuse recommended | 2A to 16 A gG (gL) |
Relay contacts | |
Rated operational current | 250V / 5A AC 30V AC / 5A DC 300 / 0,25A DC |
lowest operationl current/voltage | 100mV / 10mA AC/DC |
Connection terminals | |
Rated cross section | 2,5mm² (AWG14) flexible 4,0mm² (AWG12) inflexible |
Torque | 0,5 Nm |
Downloads